Skip to content
Blog

Lab reference ranges and critical values: a setup guide

CareSlot team ·

A lab result is only as useful as the range it is compared with. When reference ranges live in a technician's memory or on a faded chart by the analyser, flags are missed and reports vary from person to person. Setting them up once, carefully, makes every report consistent. This guide covers the process, not the numbers: your ranges should come from your own analysers, reagents and pathologist.

Start from your analyser and reagent inserts

Reference ranges depend on the method and equipment used to measure them. Take each range from the manufacturer's insert for the reagent you actually use, and have your pathologist or lab lead review the list before it goes live. When you change analyser or reagent, review the ranges again.

Set up each test with its parameters

A test such as a full blood count has many parameters. For each one, record the unit, the reference range and how the result is entered: a number, short text, or a choice from a list such as 'positive' or 'negative'. Imaging tests usually need a written report instead of values.

Add sex-specific ranges where they differ

Some parameters, such as haemoglobin, have different normal ranges for men and women. Record a separate female range where your inserts give one, so results are flagged against the right range automatically.

Define critical values

Critical values are results far enough outside the range that a doctor needs to know straight away. Agree the list and the limits with your doctors, set them on each parameter, and decide who calls whom when one appears. A result flagged as critical should never wait in a pile for verification.

Let the system flag, and the doctor verify

Once ranges are set, each result can be flagged low, high or critical as it is entered, so the technician doesn't have to check every number by eye. A doctor or lab manager then verifies the report before it goes to the patient. Until then, it should print as preliminary.

Lock verified reports

A verified report should not change quietly. If a correction is needed, it should be an amendment by a manager, logged with what changed, and verified again. Doctors and patients can then trust that a report says the same thing every time it is printed.

Review once a year

Put a date in the calendar to review the test catalogue, ranges and critical values with your pathologist, and whenever equipment or reagents change. Remove tests you no longer run so the catalogue stays easy to use.

Give your team their afternoons back.

14 days free. We’ll set it up with you, and your data stays yours if you leave.

We'll only use these details to set up your trial.